RTC Lost Power

After remove RTC coin battery, system plug-in RTC coin battery the CMOS  register 0xE access by (index port 0x70/ data port 0x71) bit 7 will be set. After check this bit, we also need to clear this bit by code.















============================================================================

在移除RTC水銀電池後,然後再次插上,這時後CMOS register offset 0xE的位址,在(使用index port 0x70/ data port 0x71)方式存取,這時候的0xE的bit 7會被設起來,在code裡面,一檢查完,就需要清掉這個位元。